PVC wire UL1569
- CAWM 1569 CSA AWM Ⅰ A PVC Insulated Wire
- Standard: UL758, 1581 CSA C22.2 NO.210.2
- Registration NO: E320487
- Marking: E 320487 AWM JINGFENG-SH 1569 VW-1 ()AWG 105'C 300V CAWM E320487 I A FT1 ()AWG 105'C 300V -F- LF
Product Description:
- -Rated Voltage: 300V, Rate temperature: 105'C
- -Tinned or bare, stranded or solid copper conductor, 32-2AWG
- -Color-coded PVC insulation
- -Passes UL VW-1 & CSA FT-1 Vertical flaame test
- -Uniform insulation thickness of wire to ensure easestripping and cutting
- -Resistant to acids, alkalis, oils, moisture And fungi
Applications:
For general purpose internal wiring of electronic and electrical equipment,where not subject to movement or mechanical damage
Conductor Type |
Conductor | Insulation | MAX Resistance At20'C |
Min Insulation Resistance |
Dielectric strength AC 1 min |
Standard length |
||||
---|---|---|---|---|---|---|---|---|---|---|
Spec | NO. | Dia | Nom.Thick | Nom.Dia | ||||||
AWG | mm | mm | mm | mm | Ω/km | MΩ/km | V | Ft(M) | ||
Standed Conductor |
30 | 7/010 | 0.30 | 0.43 | 1.16 | 354.24 | 15 | 1500 | 2000 (610) |
|
28 | 7/0.127 | 0.38 | 0.43 | 1.24 | 223.75 | |||||
26 | 7/0.16 | 0.48 | 0.43 | 1.34 | 139.75 | |||||
24 | 11/0.16 | 0.61 | 0.43 | 1.47 | 93.30 | |||||
22 | 17/0.16 | 0.76 | 0.43 | 1.62 | 55.00 | |||||
20 | 26/0.16 | 0.94 | 0.43 | 1.80 | 34.60 | |||||
18 | 41/0.16 | 1.18 | 0.43 | 2.04 | 21.80 | |||||
16 | 26/0.254 | 1.49 | 0.43 | 2.35 | 13.70 | |||||
14 | 41/0.254 | 1.88 | 0.45 | 2.78 | 8.62 | |||||
12 | 65/0.254 | 2.37 | 0.45 | 3.27 | 5.43 | 1000 (305) |
||||
10 | 105/0.254 | 3.40 | 0.48 | 4.36 | 3.41 | |||||
49/0.37 | 3.38 | 0.48 | 4.34 | 3.41 |