PVC wire UL1061
- AWM 1061 CSA AWM Ⅰ A Smei-Rigid PVC Insulated Wire
- Standard: UL758, 1581 CSA C22.2 NO.210.2
- Registration NO: E320487
- Marking: E 320487 AWM JINGFENG-SH 1061 VW-1 ()AWG 80'C 300V CAWM E320487 I A FT1 ()AWG 80'C 300V -F- LF
Product Description:
- -Rated Voltage: 300V, Rate temperature:80'C
- -Tinned or bare, stranded or solid copper conductor, 30-16AWG
- -Color-coded SR-PVC insulation
- -Passes UL VW-1 & CSA FT-1 Vertical flaame test
- -Uniform insulation thickness of wire to ensure easestripping and cutting
- -Resistant to acids,alkalis,oils,moisture And fungi
Applications:
For general purpose internal wiring of electronic and electrical equipment, Protection is required Where mechanical damage is possible.
Conductor Type |
Conductor | Insulation | MAX Resistance At20'C |
Min Insulation Resistance |
Dielectric strength AC 1 min |
Standard length |
||||
---|---|---|---|---|---|---|---|---|---|---|
Spec | NO. | Dia | Nom.Thick | Nom.Dia | ||||||
AWG | mm | mm | mm | mm | Ω/km | MΩ/km | V | Ft(M) | ||
Standed Conductor |
30 | 7/0.10 | 0.30 | 0.25 | 0.80 | 354.24 | 15 | 1500 | 2000 (610) |
|
28 | 7/0.127 | 0.38 | 0.25 | 0.88 | 223.75 | |||||
26 | 7/0.16 | 0.48 | 0.25 | 0.98 | 139.73 | |||||
24 | 11/0.16 | 0.61 | 0.25 | 1.11 | 93.30 | |||||
22 | 17/0.16 | 0.76 | 0.25 | 1.26 | 55.00 | |||||
20 | 26/0.16 | 0.94 | 0.30 | 1.54 | 34.60 | |||||
18 | 41/0.16 | 1.18 | 0.33 | 1.84 | 21.80 | |||||
16 | 26/0.254 | 1.49 | 0.35 | 2.19 | 13.70 | |||||
Single Conductor |
28 | 1/0.32 | 0.32 | 0.25 | 0.32 | 227.39 | 15 | 1500 | 2000 (610) |
|
26 | 1/0.404 | 0.404 | 0.25 | 0.90 | 142.79 | |||||
24 | 1/0.511 | 0.511 | 0.25 | 1.01 | 89.39 | |||||
22 | 1/0.643 | 0.643 | 0.25 | 1.14 | 54.30 | |||||
20 | 1/0.813 | 0.813 | 0.30 | 1.41 | 33.90 | |||||
18 | 1/1.024 | 1.024 | 0.33 | 1.68 | 21.40 | |||||
Overall Tinned |
26 | 7/0.16 | 0.48 | 0.25 | 0.98 | 139.73 | 15 | 1500 | 2000 (610) |
|
24 | 7/0.203 | 0.61 | 0.25 | 1.11 | 86.00 | |||||
22 | 7/0.254 | 0.76 | 0.25 | 1.26 | 54.80 |