Thermocouple compensation cable

Applications:

metallurgy,chemical  industry,petroleum,power generation,defense and scientific research,and cables  for connection between thermocouples and temperature display instrument.

Technical date:

Insulation:  FEP TEFLON or PVC or Silicone Rubber
Conductor:   nickel-chrome,nickel-silicone,lron,copper-nickel,copper
Temperature:  -60℃~+1000℃
Voltage:  300V/600V
Color:White-Blue-Red-Black-Brown-Yellow-Green-Transpanrent-Yellow/Green

Type of Compensating    ConductorEquipped ThermocoupleThermocouple IndexCompensating Conductor Allong-wireInsulation Layer Coloration
PositiveNegativePositiveNegative
SCPtRh10-Platinum thermocouple10SSPC   CuSNC
     Cu   Ni
RedGreen
RCPtRh13-Platinum thermocouple13RRPC   CuRNC Cu NiRedGreen
KCA/KCB/KXNi Cr- Nisi-loy ThermocoupleKKPCA Fe/
     KPCB Cu/
     KPX Ni Cr
KNCA Cu Ni/
     KNCB Cu Ni/
     KNX Ni Si
RedBlue/
     Blue/
     Black
NC/NXNi Cr- Nisi-loy ThermocoupleNNPC Fe
     NPX
     Ni Cr Si
NNC Cu Ni
     NNX Ni Si
RedGrey
     Grey
EXNi Cr- Copper-nickel ThermocoupleEEPX Ni CrENX Cu NiRedBrown
JXFe- Copper-nickel ThermocoupleJJPX FeJNX Cu NiRedPurple
TXCu- Copper-nickel
     Thermocouple
TTPX CuTNX Cu NiRedWhite

Section
     (sq.mm)

Single-strand core

Multi-strand core

Insulation
     Thickness
     (mm)

Sheath Thickness
     (mm)

Line coresDiameter
     (mm)
CoresDiameter
     (mm)
0.210.570.20.40.3
0.510.870.30.40.3
111.1370.430.40.3
1.511.3770.520.40.3
2.511.76190.410.40.3